How many cells to change

My cells are coming towards the end of the first season and i am going to bring changing them. I see some people swap cells out one at a time. I was going to change all three. Is there any reason for not swapping all at once?
Sent from my GT-I9100 using Tapatalk 2
(Online)  
Old September 23rd, 2012, 10:23 PM   #2 (permalink)
DSix36
anti-hammerhead
 
 
Join Date: Apr 2012
Location: Florida
Posts: 323
Thanks: 21
Thanked 60 Times in 39 Posts
DSix36 DSix36
Quote: (Originally Posted by Pokeystar)View Post
My cells are coming towards the end of the first season and i am going to bring changing them. I see some people swap cells out one at a time. I was going to change all three. Is there any reason for not swapping all at once?
Sent from my GT-I9100 using Tapatalk 2
By NOT swapping all out at once, you can still have some that have a proven history of reliability. Just because cells are new does not mean they will work properly or for very long. You will also be using cells from different batches so that if their is a problem with the manufacturing, they will not all crap out at once.
(Online)  
Digg this Post!Add Post to del.icio.us
Old September 23rd, 2012, 10:26 PM   #3 (permalink)
Michael Thornton
Dive Addicts
 
 
Join Date: Aug 2012
Location: Utah
Posts: 331
Thanks: 118
Thanked 61 Times in 37 Posts
Michael Thornton
Quote: (Originally Posted by DSix36)View Post
By NOT swapping all out at once, you can still have some that have a proven history of reliability. Just because cells are new does not mean they will work properly or for very long. You will also be using cells from different batches so that if their is a problem with the manufacturing, they will not all crap out at once.
Agreed. If you can do one every six months its not that much money and gives me a little more confidence in my cells. that has always been what I try to do.


Sent from my iPhone using Tapatalk
__________________
--Michael Thornton
CCR Cave Instructor
www.DiveAddicts.com
www.CCRMichael.com
TEKDiveUSA.2014 - The North American two day advanced and technical diving conference.
Miami, FL - May 17-18, 2014
(Offline)  
Digg this Post!Add Post to del.icio.us
Old September 24th, 2012, 04:59 AM   #4 (permalink)
PeterN
Supporting Member
 
 
Join Date: Mar 2012
Location: Vancouver, BC, Canada
Posts: 322
Thanks: 238
Thanked 49 Times in 22 Posts
PeterN
Some cells are faster than others. If you have a eccr, this can be a problem. A mccr is less of a problem as one can watch the cell catch up.

I need to swap out a cell soon, and am thinking of switching brands. I think I shall buy one at a time and live with the different cell speeds as I did this previously and had no issues on my mccr.

Peter
(Online)  
Digg this Post!Add Post to del.icio.us
Old September 24th, 2012, 08:02 AM   #5 (permalink)
Mark Chase
ATB=AlwaysTalkingBollocks
 
 
Join Date: Mar 2012
Location: Kent England
Posts: 500
Thanks: 66
Thanked 212 Times in 69 Posts
Mark Chase Mark Chase Mark Chase Mark Chase
Quote: (Originally Posted by Pokeystar)View Post
My cells are coming towards the end of the first season and i am going to bring changing them. I see some people swap cells out one at a time. I was going to change all three. Is there any reason for not swapping all at once?
Sent from my GT-I9100 using Tapatalk 2
Defo swap one at a time and monitor its performance against the other two known cells.

New cells can be current limited and can fail straight out of the box. Diving a unit with a matching batch of cells opens you up to potential batch failure issues.

Just because a cell is 12 months old doesn't mean its about to fail. I have run cells for two years that never failed and cells for less than a year which have.


My unit (JJ) doesn't get up set about cell errors so i tend to replace cells when they show signs of failing rather than at an specific time period. i do that by checking millivolt output and testing the cells on the dive.


ATB

Mark
(Offline)  
Digg this Post!Add Post to del.icio.us
Old September 24th, 2012, 09:25 AM   #6 (permalink)
matt
New Member
 
 
Join Date: Apr 2012
Location: London
Posts: 1,541
Thanks: 168
Thanked 74 Times in 60 Posts
matt matt matt matt
Mr rEvo gives good advice here: http://www.revo-rebreathers.com/uplo...en_sensors.pdf

I've been changing all 3 for 10 years and then doing a check-out dive before proper use. TAI cells were rock solid, now I'm inclined to go with rotation.

Matt.
(Offline)  
Digg this Post!Add Post to del.icio.us
Old September 24th, 2012, 04:47 PM   #7 (permalink)
Pokeystar
New Member
 
 
Join Date: Mar 2012
Location: Dublin, Ireland
Posts: 42
Thanks: 1
Thanked 3 Times in 2 Posts
Pokeystar
Thanks for the replies. Rotation it is.

Sent from my GT-I9100 using Tapatalk 2
(Online)  
Digg this Post!Add Post to del.icio.us
Reply

« | »



All times are GMT +1. The time now is 01:29 AM.


Powered by vBulletin® Version 3.8.5
Copyright ©2000 - 2013, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.0.0 RC4 (Unregistered)
CCRExplorers.Com ©2012 - 2012
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use
Array

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67